Isolation Transformer Products
The Isolation transformer configuration is used to generate a gross voltage (15 volts to 200 volts typical) while providing high levels of isolation as measured by corona inception and extinguish, high pot, and BIL. Usually the isolation transformer is the anchor device for any magnetic sub-system design considerations.
Isolation Transformer Configurations |
||||
| Configuration | VA Rating |
Corona-Free Level (KV) |
BIL Rating (KV) |
HIPOT Rating (KV) |
| IS1000 | 10 | 1 | 6 | 2 |
| IS1100 | 25 | 1.1 | 6 | 2.2 |
| IS2000 | 5 | 2 | 8 | 2.5 |
| IS2200 | 2000 | 2.2 | 10 | 4 |
| IS2300 | 10 | 2.3 | 10 | 2.7 |
| IS2500 | 20 | 2.5 | 12 | 4 |
| IS3000 | 75 | 3 | 12 | 5.2 |
| IS3300 | 10 | 3.3 | 14 | 8 |
| IS3500 | 150 | 3.5 | 12 | 5.2 |
| IS4000 | 250 | 4 | 12 | 9 |
| IS10000 | 200 | 10 | 60 | 25 |
| IS13000 | 400 | 13 | 65 | 42 |